Downlight spacing calculator: an even grid from the spacing criterion
How far apart recessed downlights can sit for even light, from the spacing criterion on the fixture's photometric report and the height above the surface you want lit, and a grid that fits the room.
This is a planning grid for one fixture and one surface. It answers whether the light will spread evenly, not whether the room has enough of it, and it knows nothing about the joists, ducts and wiring above the ceiling. Recessed lights are electrician work: the electrician lays out the final grid from the fixture's sheet (Working with an electrician). Ask the authority
Space downlights from the fixture
Enter the room, the ceiling height, the height of the surface you want lit evenly and the spacing criterion from the downlight's sheet. The calculator gives the maximum spacing, the fewest downlights each way that stay at or under it, the spacing that leaves, and the distance from the walls. Layers, fixtures and glare explains why spacing comes from the fixture and not from a rule of thumb.
Two separate checks. The count here is the fewest downlights that spread light evenly. The count from the Light calculators is how many lumens the room needs. They answer different questions, and a plan has to pass both: an even grid can still be too dim, and enough lumens in too few downlights leaves pools of light with darker gaps between them.
Assumptions behind the spacing calculator
- The spacing criterion. A ratio on a fixture's photometric report: the spacing, relative to the mounting height, at which a uniform grid of that fixture gives uniform light on the work surface. Lighting Analysts' documentation lists three values (along each axis and diagonally) and says to use the lowest (AGi32, IES Indoor Report Summary). It differs from one downlight to the next, so the calculator needs the figure from your fixture's sheet and does not assume one. Product-specific
- The height it multiplies. Maximum spacing = spacing criterion × the height from the fixture to the surface lit, not to the floor. Prudential Lighting's continuing-education course on BNP Media's CE Center works it for a 9 ft ceiling and a 30-inch desk: 1.4 × 6.5 ft = 9.1 ft, center to center. Cornell's zonal cavity notes define the ratio the same way, by the height above the work plane. A recessed downlight sits at the ceiling, so the calculator takes ceiling height minus surface height. Physical principle
- The surface. The default, 2.5 ft, is the desk in Prudential's example. Enter 3 ft for a kitchen counter, as in Layers, fixtures and glare, or 0 for the floor; the Defense Department's housing criteria measure living rooms, hallways and kitchens' general light at the floor (UFC 3-530-01, 2023, section 3-9). The lower the surface, the farther apart the same fixture can sit.
- The grid. Along each side, the calculator takes the fewest downlights whose spacing is at or under the maximum: the side's length divided by the maximum spacing, rounded up. The spacing is then the side's length divided by that number. Where a side is shorter than one spacing, one downlight sits in the middle.
- Half the spacing from the wall. ERCO's design guide recommends half the spacing as the distance from a downlight to the wall (ERCO, Arranging luminaires). That is one maker's rule of thumb; we found no free standards source for it. Convention
- Figures not for your fixture. Prudential's course calls 1.2 or 1.4 fairly common for commercial fixtures and 1.8 high; ERCO gives up to 1.5 times the height above the working plane as a rough guide for its downlights. The calculator shows these when the criterion is blank and lays out no grid from them. Product-specific
- Rounding. Distances are shown to the nearest inch.
See it with a fictional room
Tunde and Sam's kitchen is 13 by 12 ft with an 8 ft ceiling and 3 ft counters. Their general contractor's drawing shows eight downlights. Suppose the sheet for the downlight they are offered gave spacing criteria of 1.3, 1.3 and 1.2 (an illustrative example, not a real product). The calculator takes the lowest, 1.2, times the 5 ft from the ceiling to the counter: a maximum of 6 ft 0 in. Three along the 13 ft side, 4 ft 4 in apart and 2 ft 2 in from the end walls; two across the 12 ft side, 6 ft 0 in apart and 3 ft 0 in from the side walls. Six downlights is the fewest that spread light evenly on the counter.
That does not make eight wrong. A grid of eight is closer than the maximum, so it is even too. Whether six or eight give enough light is the lumen check on the Light calculators page, and where each one goes around the joists is the electrician's layout (Kitchens, bathrooms and desks). All figures are invented for the example.